PHYSICAL
Weight: 11 ounces (with batteries).
Size: 2.5 W x 5.17 H x 1.24 D inches (63.5 W x 131.3 H x 31.5 D mm).
Operating Temperature: -22° to 167°F (-30° to 75°C).
Case: Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed).
KEYPAD
Sealed membrane that is resistant to both water and petroleum products.
9 tactile-feedback keys.
TRANSDUCER
Single-element (delay line & contact)
5 to 20 MHz frequency range.
Locking quick disconnect LEMO 00 connector.
4 foot cable.
Custom transducers available for special applications.
CERTIFICATION
Factory calibration traceable to NIST & MIL-STD-45662A.
WARRANTY
5 years limited
POWER SOURCE
Two 1.5V alkaline, 1.2V NiCad, or 1.5V lithium AA cells.
Typically operates for 35 hours on alkaline and 18 hours on NiCad.
Low battery indicator on display. Auto shutoff after 5 minutes of inactivity.
Line power USB-C connected to PC or power adapter.
DISPLAY
Multi-function 7 segment 4.5 digit liquidcrystal display with 0.500 in digit height.
Two 0.125 in14 segment fields for labels and values, and one 7 segment field for labels and values. Additional icons to indicate features and modes.
Backlight is selectable On/Off/Auto, and selectable brightness (Lo, Med, Hi) options.
Bar graph indicates stability of reading.
SOFTWARE
Comes complete with USB download cable (PZX-7 DL). No software required, comma separated file type (.csv).
MEASURING
Measurement Modes:
Pulse-Echo (P-E): 0.040 to 36.0 in (1.0 to 914.4 mm).
Echo-Echo (E-E): Delay line – 0.006 to 1.00 in (0.152 to 25.4 mm). Contact – 0.040 to 6.0 in (1.0 to 152.4 mm).
MEASURING (CONT’D)
Interface-Echo (I-E): Delay Line – 0.060 to 1.0 in (1.524 to 25.4 mm).
Plastics (PLAS): Graphite Delay Line – 0.005 to 0.250 in (0.127 to 6.35 mm). Ranges dependent on transducer type, material type, transducer frequency and diameters.
Units: English & Metric (Low & High resolution).
Resolution: 0.001 or 0.0001 in (0.01 or 0.001 mm).
Velocity Range: 0.0120 to .7300 in/μs (305 to 18,542 m/sec).
PRF: 200Hz Display Update Rate: 10Hz
Gain: Automatic or manual control.
Time Dependent Gain (TDG): Implemented in all measure modes.
FEATURES
Transducer Types: Single delay line & contact styles. Selectable diameters for contact style.
High Speed Scan: Display the lowest reading found during a scan. Scan speed at 100Hz.
Differential Mode: Display the +/- difference from a nominal value entered.
Alarm Mode: High & low alarm limits with audible and visual indicators.
VX velocity: Measure in terms of velocity for nodularity testing.